Description
Description:
By establishing a convenient and safe central venous channel, ALSPL CVC is widely applied in clinical emergency rescue, intensive care drug administration during medical treatment and surgery, blood infusion, parenteral nutrition and monitor of central venous pressure with blood pressure transducer. The connector in ALSPL CVC employs ALSPL proprietary design, which makes the connector smooth and firm, effectively preventing infection, leakage, and shedding.
Latex Free
Complete custom kits also available on request.
Specifications
Type | Lumen Size (Ga) | Catheter Length (cm) | Dialator (Fr) | Introducer Needle | Guidewire (dia” x cms) | Flow Rate Distal (ml/hr) | Flow Rate Middle (ml/hr) | Flow Rate Proximal (ml/hr) | Introducer Needle Type |
---|---|---|---|---|---|---|---|---|---|
Single-lumen | 14G | 15 | 8Fr | 18G x 7 | 0.035″x45cm J Tip | 7200 | – | – | 18G |
14G | 20 | 8Fr | 18G x 7 | 0.035’x45cm J Tip | 7200 | – | – | 18G | |
16G | 15 | 7 Fr | 18G x 7 | 0.035’x45cm J Tip | 3600 | – | — | 18G | |
16G | 20 | 7 Fr | 18G x 7 | 0.035″x45cm J Tip | 3600 | – | – | 18G | |
18G | 15 | 5 Fr | 20G x 4 | 0.021’x45cm J Tip | 1500 | — | — | — | |
18G | 20 | 5 Fr | 20G x 4 | 0.021″x45cm J Tip | 1500 | — | – | — | |
20G | 13 | 4Fr | 20G x 4 | 0.018″x45cm J Tip | 600 | — | — | — | |
22G | 6 | 5 Fr | 20G x 4 | 0.018″x45cm J Tip | 840 | — | 600 | – | |
22G | 8 | 5 Fr | 20G x 4 | 0.018″x45cm J Tip | 840 | — | 600 | – | |
22G | 15 | 5 Fr | 20G x 4 | 0.018″x45cm J Tip | 840 | — | 600 | — |
Type | Lumen Size (Ga) | Catheter Length (cm) | Dialator (Fr) | Introducer Needle | Guidewire (dia” x cms) | Flow Rate Distal (ml/hr) | Flow Rate Middle (ml/hr) | Flow Rate Proximal (ml/hr) | Introducer Needle Type |
---|---|---|---|---|---|---|---|---|---|
Double-lumen | 18G.20G | 8 | 6 Fr | 20G x 4 | 0.021″x45cm J Tip | 1290 | — | 990 | — |
18G. 20G | 15 | 6 Fr | 20G x 4 | 0.021″x45cm J Tip | 1290 | — | 990 | — | |
14G. 18G | 16 | 8 Fr | 18G x 7 | 0.035’x45cm J Tip | 5100 | — | 3300 | 18G | |
14G, 18G | 20 | 8 Fr | 18G x 7 | 0.035’x45cm J Tip | 5100 | — | 3300 | 18G | |
20G, 22G, 22G | 16 | 6 Fr | 20G x 4 | 0.018’x45cm J Tip | |||||
20G, 22G, 22G | 8 | 6 Fr | 20G x 4 | 0.018″x45cm J Tip | — |
Type | Lumen Size (Ga) | Catheter Length (cm) | Dialator (Fr) | Introducer Needle | Guidewire (dia” x cms) | Flow Rate Distal (ml/hr) | Flow Rate Middle (ml/hr) | Flow Rate Proximal (ml/hr) | Introducer Needle Type |
---|---|---|---|---|---|---|---|---|---|
Triple-lumen | 16G.18G.18G | 13 | 8 Fr | 18G x 7 | 0.035’x45cm J Tip | 3120 | 1560 | 1560 | 18G |
16G,18G,18G | 16 | 8 Fr | 18G x 7 | 0.035’x45cm J Tip | 3120 | 1560 | 1560 | 18G | |
16G,18G,18G | 20 | 8 Fr | 18G x 7 | 0.035’x45cm J Tip | 3120 | 1560 | 1560 | 18G |